(AS3996:2019) Load Classification – Everything you need to know

Access Covers Australia manufacture products such as access covers and grates to classes A, B, C, D, E, F and G according to load capacity as set out in below table.
Share

Access Covers Australia manufactures access covers and grates to all seven AS 3996 load classes, from Class A to Class G, according to load capacity as set out in the table below

Testing of covers and grates shall be in accordance with AS 3996. The appropriate class for a cover or grate depends upon the location of the installation. The selection of the appropriate class is the responsibility of the designer, and where there is doubt, the stronger class shall be selected.

Specifics of the location should be taken into consideration when selecting the right cover or grate. The speed of traffic, wheel type and the physical position (turning area) should all be assessed.

Reference: AS3996:2019 – Standards Australia

What is AS 3996?

AS 3996:2019 is the Australian Standard for access covers and grates. The AS 3996 load classes run from Class A for pedestrian areas to Class G for ports and airports, and the standard specifies how covers and grates must be tested to prove they can carry their rated load safely.

How to choose the right load class

The right load class depends on the heaviest load that could ever travel over the cover or grate, not just the traffic you expect day to day. Under AS 3996, choosing the class is the designer’s responsibility, and if you’re in any doubt, you should always choose the stronger class. A cover that’s under-rated can crack, rock or collapse, creating a serious safety risk and an expensive replacement.

Start with the heaviest vehicle that could use the area. A footpath may only see pedestrians most of the time, but if a council truck, delivery van or garbage truck could ever drive or park on it, the cover needs to be rated for that vehicle. Think about access during construction, maintenance and emergencies too, not just normal use.

Also, consider how vehicles move over the cover. Covers in turning areas, at intersections, on ramps or near loading bays take extra force from braking, accelerating and turning wheels. Fast-moving traffic also adds impact loads. Covers in these positions often need a higher class than the vehicle weight alone suggests.

AS 3996 load classes table

AS 3996:2019 Load Classification Table — Access Covers Australia
AS 3996:2019 load classification table, Class A to Class G, with typical use, nominal wheel loading, serviceability design load and ultimate limit state design load.
Class Typical Use Nominal Wheel
Loading (kg)
Serviceability
Design Load (kN)
Ultimate Limit State
Design Load (kN)
Vehicle type
A Areas (including footways) accessible only to pedestrians and pedal cyclists, closed to other traffic (extra-light duty). 330kg 6.7kN 10kN Pedestrians and cyclists
B Areas (including footways and light tractor paths) accessible to vehicles (excluding commercial vehicles) or livestock (light duty). 2,670kg 53kN 80kN Light tractors and livestock
C Malls and areas open to slow-moving commercial vehicles (medium duty). 5,000kg 100kN 150kN Slow-moving commercial vehicles
D Carriageways of roads and areas open to commercial vehicles (heavy duty). 8,000kg 160kN 240kN Commercial vehicles and roads
E General docks and aircraft pavements (extra heavy duty – E). 13,700kg 267kN 400kN Docks and aircraft pavements
F Docks and aircraft pavements subject to high wheel loads (extra heavy duty – F). 20,000kg 400kN 600kN High wheel loads, docks
G Docks and aircraft pavements subject to very high wheel loads (extra heavy duty – G). 30,000kg 600kN 900kN Very high wheel loads, aircraft

Notes:

  1. Nominal wheel loads are given for guidance only. Consideration should be given to the type, size and pneumatic pressure of the load
  2. Class B design loads exceed AS 5100.2 requirements for footway
  3. Class D design loads exceed AS 2 requirements for a W80 wheel load.
  4. Class C units are based on an intermediate
  5. The serviceability load is set at 2/3 of the ultimate limit state design load.
  6. A force of 1 kN approximately equal to the weight of 100 kg.

View our extensive range of Access Covers.

View our extensive range of Grates.

These are general guides only. Every site is different, so if your project involves heavy vehicles, forklifts, turning traffic or anything unusual, talk to our engineering team before you specify. Call (03) 9335 5355 or send us your plans, and we’ll recommend the right class for each location.

Interested in reading more?

September 21, 2026

Access Covers Australia Achieves AS/NZS 5131 CC1 Steelwork Certificate of Compliance

September 15, 2026

Access Covers Australia is the winner of the Ecosystem Partner of the Year award!

August 30, 2025

Your Guide to Procuring Fire-Resistant Multipart Covers

July 17, 2025

Why Project Managers Choose Precast Concrete Solutions over In-situ options

May 13, 2025

Access Covers Australia Partners with Municipal Works Australia

February 26, 2025

Collingwood and Access Covers Australia celebrate extension

December 18, 2024

2024 year in review: Guiding our clients through every step of the way!

March 25, 2024

Access Covers Australia achieve full Intertek SAI Global Industry Certification

April 6, 2021

Easy lift Cover

April 6, 2021

SpeedyFORM: Faster Trench Drain Installation in One Pour

Please select your preferred language:

Get Started

Request a quote today

Complete the form below and our team will review your requirements before preparing a tailored quote.

Filter

Drawings Category Filter